A purchase order for "1.0 mm² red ferrules" leaves a dimension unresolved. In the JINH E series, both the E1008 and E1012 suit a nominal 1.0 mm² conductor, yet their metal tubes differ by 4 mm. To choose a wire ferrule length for a terminal block, identify the receiving terminal, check the ferrule dimensions it accepts, then specify the exact ferrule code on your harness drawing.
Three lengths on two different drawings
| Dimension | Where to find it | How you use it |
|---|---|---|
| Metal tube or contact length, F | Ferrule drawing | Compare the metal portion with the receiving terminal's specified ferrule range. |
| Overall ferrule length, L | Ferrule drawing | Check the length including the insulating collar and available access around adjacent wires. |
| Wire stripping length | Approved preparation instructions for the selected wire and ferrule | Set the wire-preparation operation. Keep this as a separate field from F and L. |
If the terminal sheet gives only a bare-wire strip length, ask the maker for the accepted ferrule type and dimensions. A published number for bare conductor preparation does not settle the permitted length of an insulated ferrule. Equipment makers may identify individual ferrules and tools for particular terminals. Use the row that corresponds to the equipment and conductor you intend to buy.
E1008 and E1012 accept the same nominal conductor size. Their metal tubes and overall lengths differ.
A 1.0 mm² example from the JINH catalog
| JINH item | Nominal wire area | Metal tube F | Overall L |
|---|---|---|---|
| E1008 | 1.0 mm² | 8.0 mm | 14.6 mm |
| E1012 | 1.0 mm² | 12.0 mm | 18.4 mm |
Suppose the equipment maker specifies an 8 mm metal tube for the chosen insulated ferrule and wire. E1008 is the candidate to submit for checking. E1012 shares its wire size and still falls outside that dimensional requirement. If the maker also specifies an approved crimp profile or outside dimension after crimping, check those before approving the sample. The values above come from the JINH Crimp Terminals catalog, printed page 9.
When two wires share a connection
Write the conductor count explicitly on the drawing. "2 × 0.75 mm²" gives the supplier a different requirement from "1 × 1.5 mm²." With two conductors, first establish that the receiving terminal permits that twin-ferrule combination. Then check both wire entries, the finished crimp dimensions and collar clearance at adjacent positions. JINH's TE twin cord end terminal has its own dimensional table.
What to record at sample approval
Use the production wire, actual terminal and proposed production tool on the sample. Record the equipment terminal code, ferrule item, conductor construction, tool and die, and approved preparation setting. Have your assembly team check seating, strand containment and access to adjacent positions against the manufacturer's instructions. Use the project's specified mechanical acceptance test where applicable. A photo of the finished sample helps receiving staff spot a changed collar or substituted item on a repeat order.
Questions from the purchasing desk
Can I identify the ferrule by collar color? A color convention helps stores pick parts within an agreed range. Put the item code, conductor size and tube length on the order as well. JINH lists color options on its E-type cord end terminal page.
What if the distributor offers an "equivalent" with the same metal tube length? Request its drawing and compare collar dimensions, conductor range and crimp-tool requirements. A different collar can interfere with a neighboring terminal even when F is identical.
Can I use one ferrule across several machines? Build a cross-reference with one row per equipment terminal. Consolidate stock only after each row accepts the same ferrule and prepared conductor.
A purchase description your supplier can quote
For an approved single-wire sample, a usable line reads "E1008, 1 × 1.0 mm², F 8.0 mm, L 14.6 mm, collar color per drawing, quantity per pack as quoted." Include the equipment terminal reference and drawing revision when asking JINH to review a substitution.